If the HP Custom ISO or the HP Offline Management Bundle was installed, then no changes are required to use a solution based on Agentless Management vs the full HP Insight management WBEM Providers and visa-versa.

This article applies to PRTG Network Monitor 12 or later HP ProLiant system health sensors They are now included out of the box in PRTG (works for Windows drivers and most Linux drivers). But we got this note from a customer: I did install the HP Insight Management Agents on my Windows 2008 R2 servers along with HP System Management Homepage. Canon Ir2270 Ir2870 Pcl5e Scanner Driver.

After doing so, PRTG was able to configure sensors for just about everything except the Smart Array controller and it's drives. After consulting with HP, they had me to also install the Insight Management WBEM providers agent. Once installed, now PRTG can get SNMP data from the RAID controller. I don't have the WBEM provider installed on any of my Windows 2003 servers, so, it appears this is a must for Windows 2008, or at least with 2008 R2. You can download the installers for the required software here: • •. This would be a very nice new sensor: check overall Proliant Health.

I've looked into using SNMP/WBEM to check hardware values but this requires creating a lot of sensors because there isn't a general health value available. Hp Jetdirect J3265a Firmware Update. (cooling, management, memory, power, processors, array, disks, nics.) HP also uses a lot of MIB files which makes it very time consuming and difficult to find all values.

The only way of checking overall health is to look at the HP System Management page. It would be cool if the pro's at Paessler could achieve this:). I am not able to import the HP mib files, as there is no sinlge *.mib file but: ---- cmaobjects.conf: /opt/hp/hp-snmp-agents/mibs/cmafdtnobjects.conf /opt/hp/hp-snmp-agents/mibs/cmasvrobjects.conf /opt/hp/hp-snmp-agents/mibs/cmanicobjects.conf /opt/hp/hp-snmp-agents/mibs/cmastorobjects.conf ---cmaobjects. Windows 7 Printer Drivers Epson C60 Troubleshooting. mibdef: cpqHoMibRevMajor 1.3.6.1.4.1.232.11.1.1 INTEGER read-only mandatory cpqHoMibRevMinor 1.3.6.1.4.1.232.11.1.2 INTEGER read-only mandatory cpqHoMibCondition 1.3.6.1.4.1.232.11.1.3 INTEGER read-only mandatory cpqHoOsCommonPollFreq 1.3.6.1.4.1.232.11.2.1.4.1 INTEGER read-write mandatory. --- cmaobjects.regmib: cpqHoFileSysIndex host/filesys TABLE 1 cpqHoFileSysDesc host/filesys TABLE 1 cpqHoFileSysSpaceTotal host/filesys TABLE 1 cpqHoFileSysSpaceUsed host/filesys TABLE 1.